Barotrauma reactor controller. The problem with typhoon is it still use legacy items, wiring and small ballast. Barotrauma reactor controller

 
 The problem with typhoon is it still use legacy items, wiring and small ballastBarotrauma reactor controller  it uses an PI controller to manage the reactor load

Barotrauma. This guide does not build a turbine controller. Place your !explosive in there 3. #footer_privacy_policy | #footer. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. ) Then you have the REALLY good. Flee or fight alien lifeforms, explore a strange new world, command your crew, and craft equipment in a tense 2d co-op experience. 0 (barring any unexpected delays), so now is a fitting time to say thank you once. The 600 degrees per 1000 kW may differ depending on the sub's reactor settings, but this even further demonstrates that the inflexibility of this controller is not ideal. Focusing on ease-of-installation for missions and fuel efficiency and other upgrades for campaigns A turbine control can be done very easily with 2 components. They can absorb excess power when the Nuclear Reactor overproduces and threatens to overload and damage connected devices. Bradinator519 Jan 3, 2020 @ 12:07pm. They contain a wealth of material loot, and often also have Creatures lurking inside. It allows remote control of a submarine's nuclear reactor, except for the movement of fuel rods. 1. Turn off reactor and wait until its lights are out => reduce repair failure to 0%. I've added a section with answers for your other questions. . Flee or fight alien lifeforms, explore a strange new world, command your crew, and craft equipment in a tense 2d co-op experience. All Discussions Screenshots Artwork Broadcasts Videos Workshop News Guides Reviews. Stop the Orca 2 to a halt, maintain position, lower the charge rate of Super-capacitators and Batteries, and then you should have enough power for the Fabricator. These are very strong; some people call them overpowered, because they mean the captain doesn't need to worry about overloading the grid and the engineers don't have to keep. Wire a fuel indicator. the lower your helm skill is, you are just not used to use the buttons and switches on the console, thus hampering. I feel like nerf of auto-reactors in Barotrauma is just like Whiplash nerf in ULTRAKILL : was needed, but too hard. Knowlton V2. 01 * Reactor's max output" 2) Divide for "Load value / (0. Welcome to Europa!. Most controllers have the right power production targets, but do not actually adjust production fast enough, because the fission and turbine needles get slower the closer they are to the target production. In Barotrauma you're a submarine crew member beneath the ice of Jupiter's moon. Although I suppose as long as you aren't the one doing the. Wrecks can spawn on rocks the sea floor of a level, at all difficulties. Humpack, Poor drainage, only one big pump, ON THE REAR!Barotrauma submarine editor tutorial. Összes Témák Képernyőmentések Alkotások Közvetítések Videók Műhely Hírek Útmutatók Értékelések. I swear to the old 2-component bang bang controller. Remora. Top stuff. 5-component is frequent version that will prevent many issues with reactor and allow have much less over/undervoltages in general. It controls all the big lights on the sub, but not the emergency lighting. 2*. com. Trust me it'll save lives. It used a logic control system to make sure the output of the reactor always matches the demand of the battery it is connected to. Although I suppose as long as you aren't the one doing the. r/Barotrauma • Me managning reactor while the capitan has been bored for 0. Barotrauma. Though much faster than automatic control, circuit control also takes some time to. But I decided I wanted to go further so it could be used throughout the game without being. Sadly I do this, I might give you DIY reactor controllers and special ballast tanks but sometimes if the railgun happens to trigger 2-3 C-4 Denotators that were place literally 10-15 rounds ago that "Wasnt" meTrying to start a solo campaign, Tried both with the Barsuk and Dugong. This is just one solution, for a very common case. Barotrauma прохождение, Barotrauma tutorial. I have not yet figured out how to put the power and load of each junction box into wiring components. It doesn't solve the junctionbox overvoltage problem though. Barotrauma Barotrauma Workshop You can build your own submarines and monsters with in-game editors and share your creations with other players. If the load drops suddenly and the reactor can’t compensate, all of your junction boxes get overvoltaged and break, possibly starting fires. Only issue I have is that you need to turn off and on the reactor when switching fuel rods, otherwise it risks overheating and catching on fireI want to make a simple contraption that whenever the reactor output is to high then a signal is send to alarm buzzer can someone explain how to do it im pretty much clueless with logic gates. What junction box screen and what the reactor tells you for load_out will be different. In Barotrauma terms--on an in-game reactor, SET_FISSIONRATE and SET_TURBINEOUT are both parameters that can be controlled by. 47K subscribers in the Barotrauma community. View All. That's good. 01 * Reactor's max output) [1]" which is our Turbine output 3) Memory for 75. The reason it's getting nerfed, from what I've heard, is that it goes against the Dev's vision of having the electrical engineer stay at the reactor to manually adjust the reactor. Subscribe to downloadAntoneeees Auto reactor room. Basically the opposite of a concatenation component. IMO it may make it easier to understand for the newer folks, and also reduces a component. If you manage the reactor properly, you can power everything while keeping fission low and more than doubling fuel time. Remora: 5000. Well thought out automatic reactor controller systems will improve the automatic controls reaction time when adjusting fission rate and turbine output. I am modding a ship to use for the entirety of a multiplayer campaign. The reactor would go into box 1, all lights can be on a relay, the two small pumps can be on a relay. Equip the Screwdriver and hover your mouse over the Greater Component and press the E Button. PID (proportional, integrative, derivative) is a general logic mechanism used for automated system control. If I could get the power and load on. In the most current unstable build of barotrauma they have actually nerfed most if not all automated reactor component controllers. The AI is in a DESPERATE need for a significant overhaul. Despite the sliders being instant for humans to adjust, the intended manual control of the reactor remains unengaging and lacks complexity. She was spoiled by the auto-reactor being able to flawlessly handle the reactor. It's for any kind of input handling. If you're in game, use a memory component, enter what you want it to say, and then attach the memory output to the text display input. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. average barotrauma captain returning to the ship after leaving the engineer alone for too long. Here are some things to consider. #footer_privacy_policy | #footer. When the components are correctly configured the sliders will bounce between 0 and 100. A reactor is useless with broken junction boxes. This is all about Barotrauma – Guide for Ship Reactor for Better Automatic Control in Barotrauma; I hope you enjoy reading the Guide! The " Carnot " Component System is very modular and this is the simplest, while at the same time effective, module. All trademarks are property of their respective owners in the US and other countries. Barotrauma - Orca class submarine overview. Flee or fight alien lifeforms, explore a strange new world, command your crew, and craft equipment in a tense 2d co-op experience. You can see the current status of your reactor by looking at its sprite. I like the winterhalter more. Unlike the default automatic control they are insanely fast at reacting to load fluctuations. 198 votes, 58 comments. I think a post about 1-component controller has already appeared. R-29: 5200. 6. 4)/2 = . 98. 6 player classes with different skills and tasks: Captain, Engineer, Mechanic, Medic, Security officer and Assistant. In single-player you can switch control to any crew member, and a bot will take over the character you were. Batteries can be useful for stabilizing the submarine's power. Don’t be scared of the manual control. 78 votes, 45 comments. The battery then powers the junction boxes directly. Flee or fight alien lifeforms, explore a strange new world, command your crew, and craft equipment in a tense 2d co-op experience. Just a suggestion. Increasing the benefits of manual reactor control is a good thing, but making reactor controllers favored by casual players unusable without any kind of in-game notice or warning is ultimately going to upset people as it's legitimately not their fault their submarine burned to a crisp because it's a known-good system that caused the fire. 6GHz. This issue was present before the implementation of the current solution, which did not address the underlying. Nuclear reactor and power grid. I was mastering my reactor job as engineer for a few missions, came up with keeping temperature at the minimal possible level to produce energy to save rod/rods charge, so I was keeping temperature level equal to the lowest orange temperature bar and, of course, was adjusting turbine output to stay in green zone. Congratulations, it is very well made. The best option in terms of simplicity, safety and performance is the Temperature of 5000 degrees and is the Temperature that this first part will utilize. First, determine the max output of your reactor. com So got back into the game for 1. So assuming a steady 40% fission rate: (. Barotrauma. I’ve been doing a little research and I see automatic reactor controls have been nerfed. by Orum. . Trust me it'll save lives. Basically my wife just doesn't want to play anymore with the reactor being sluggish like it is now. 1. Play with up to 16 players on board a submarine. The unstable beta reactor is terrible, imo. Otherwise you can simply add more Fuel Rods into your reactor. The thing to remember about reactor controllers is that most of the commonly known designs do not take into account environmental high load influences, if one of these factors sends the load sky-high then the fission rate could be. The reactor is giving constant power to the battiers, and the batteries are regulating the poweroutput automatically. You must carefully manage the reactor's Fission Rate to manage the heat from the extra rods. Best way to deal with power spikes without sub editor is:Making automated reactor controll from components. When held, it shows the interface of the controlled Nuclear Reactor, including the conditions of its Fuel Rods. the default controller should be ok if u put in the fuel rods slow enough. Known weak performance. >Plays Solo. All Discussions Screenshots Artwork Broadcasts Videos Workshop News Guides Reviews. Shutting down the reactor doesn’t automatically turn off automatic control. All Discussions Screenshots Artwork Broadcasts Videos Workshop News Guides Reviews. Run the docking port power through a relay (which acts as a one-way diode, no power will go from your sub to the station), when docked to a powered station your reactor will automatically slow right down to minimal output so your fuel will hardly get used. Let me describe in 2 words: I don’t know where to start with this…. Bots don't anticipate a. It is not sold. The ongoing issue here is that all the auto controllers are less efficient now, though most can still reduce or eliminate a meltdown, they won't help. In essence it is an 11 component reactor design that I took from Antoneeees and upgraded it with several features. Add all DLC to Cart. Welcome to Europa!. I do not want to spend all my runs of this game managing the reactor its incredibly annoying since the devs do not make the regular reactor controller work by itself. Don't recall entirety of it but tl;dr was "awesome but impractical, barely if at all better than reactor's normal auto controller". Ensure both dials are set to 0. Of reactor controllers that I have reviewed all express an incomplete understanding of the reactor's mechanics. The Herja has a decent power draw from its twin engines and if you're working with a default automatic reactor and not taking care with your piloting, it's real easy to set the ship afire by overvolting your boxes. I suggest using this graphite schem. Now there is a reason to attend the reactor and even a bonus for doing so. (e. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. In Barotrauma you're a submarine crew member beneath the ice of Jupiter's moon. Barodrama. 😎Barotrauma memes🤡skibidi bop mm dadaThe power management for the Orca is a bit crummy by default, I think the most effective way is to force the batteries to just buffer the reactor output, put it in manual control at 2500-3000KW and leave the batteries enabled at 100% charge rate, they should buffer any difference. emergency lights are usually off when there is an. Did u try turning off and on? the_mr_pickles • 3 yr. SUBSCRIBE: me on discord: up to date on Twitter: I show you how. Easy reactor output control system. You can alter the expression of the REGEX component [1-x] to be as high as 9. Athena. Credit for the 7-component controller: value (output=1; false output BLANK; use captur. Barotrauma. Following Rob Smith's reactor controller guide [1] and his amazing turbine controller, I put some time into researching how the reactor temperature system works and came up with a pretty good fission controller. 12/11/2022 DrFreenote No Comments. My mate's computer crashes. In-depth Reactor Guide and Fission Controller (last updated for 0. It used a logic control system to make sure the output of the reactor always matches the demand of the battery it is connected to. Fire can also occur from exceeding this temperature for a different, often smaller timer duration (these durations can be found in the editor on the nuclear reactor entity). Before the update, all methods of automated reactor control seemed to work fine. If reactor is badly damaged wear a diving suit (PUCS grants high resistance) and stack with a hazmat suit and iodide potassium before proceeding as usual to prevent getting instantly fully irradiated/contaminated. I find the best strategy is to hire a disposable character, give them a gun, seal the reactor room door. the only way to fix this is to make every device you power send a signal ahead of time to the reactor. Steps To Reproduce. as far as fuel goes, I built the 7-component controller described here (it's a workshop item for a canned Assembly in the sub builder, but you can just build it by hand in-game perfectly well without downloading or installing anything); it runs far more efficiently than the stock reactor autocontroller (and will fry your junction boxes far less during evasive maneuvers. The latter is what Barotrauma is mostly concerned with, being a game set in a leaky submarine where a watery death awaits the crew if they don. A Workshop Item for Barotrauma. you're proly gonna want to go with larger component reactor controls, starting with the 5 component controller, with more precise controllers requiring more pieces and even sub assemblies. Second, overvoltage can be a good thing now. Mrs. I definitely agree with the first comment, however. I get slow downs when loads of AI suddenly. . 4)/1 = . Ya no the controller works perfectly it seems to just be that the output can't keep up with the load. Welcome to Europa! In Barotrauma you're a submarine crew member beneath the ice…In-depth Reactor Guide and Fission Controller (last updated for 0. Here are some things to consider. com. Hiya, I am trying to figure out how to create a load balancing system for the batteries. you either need to buffer the engine with dedicated batteries or you need to use manual control on the helm to slowly ramp up engine thrust instead of jacking it to 100% immediately. Some items are not possible to include in the game. This guide does not build a turbine controller. Operate complex on-board systems and devices like the sonar, nuclear reactor, weapons, engines and. So first it is; water detector -> signal check (output -100) -> pump: and that works as expected. 2 Turbine Output 2. I can just offer you the guide here, it has several different reactor controllers to choose from. #footer_privacy_policy | #footer. ago They've known for a long time, I picked the game up very shortly before the 1. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. From the steam workshop: Reactor controllers are circuits that work as much improved automatic control option for the. . Swap engine thrust and buoyancy wires to cause a crash. false output should be zero. EDC timing and reactor controller are also important. 13. I'm wondering if anyone has fully upgraded the orca 2 and if it can get to the point where reactor output can meet the load with uraniumNot so, this is a reactor controller that works quite well Formulas are Turbine output = Load value / (0. The single player is borderline unplayable due to how bad the AI currently is. So, autoreactor nerf. I can upload screenshot if needed, but my wiring and components are the same as all the video, so im curious why nothing is happening. Although I suppose as long as you aren't the one doing the. It is still way faster than the automatic control and handles two rods it seems. 3 of them are new reactors made by me, and 1 of them is the famous two component reactor. You can alter the expression of the REGEX component [1-x] to be as high as 9. Also you can react faster on load changes, witch your electronics last longer, keeps faster movment up for your navigator and so on. You can liken it to the cruise control system on a car, controlling the accelerator to maintain a certain speed. In this mod you will find: A submarine file containing pre-wired assemblies for new-style Magic Reactor Controllers for your learning pleasure. Now, press ESC to exit. Turn off reactor and wait until its lights are out => reduce repair failure to 0%. This is just one solution, for a very common case. It's more compact and stackable, just end the chain with an inverted coal sorter so that it doesn't overflow. In my experience the main benefit from having a reactor controller as a solo player is probably not having to replace rods as often, so with a controller one could just fill it with four rods, the controller manages the temperature, but as this is now much slower. Barotrauma. It's supposed to allow perfect efficiency. Go to Barotrauma r/Barotrauma. There are lots of fun ways to optimize the ship: automatic reactor control, automatic oxygen system to save power when there's enough oxygen, on/off switches for fabricators, etc. Which would be a linear decrease in fuel consumption, however this isn't the case x is a function of y and when we increase the number of rods we. Enable Mouse LookIf you're in the sub editor, you can just type the text. If the control panel on the front of it is blue, you're golden! A blue control panel means that the reactor is at 100% health. 3. ago. Since two component "Bang-Bang" style reactor controllers were removed from the game with the release of the "Hoist the Sails" update, this guide aims to provide a suitable alternative. The 46. No4Delirious [author] Oct 20, 2021 @ 11:57pm. 19 Dip2pot4t0Ch1P • 6 hr. The main issue would be to be sure the message is only broadcasted once (or at least once ever 10 sec) so you might want to add a check that only reset once you have changed the fuel rod (value get higher than 10). Barotrauma. I. It has a idle power usage constant that it uses to decide if it needs to go to overvoltage or under voltage mode, a Pd controller for sharper turns, an overheat protection AND a voice. You can pair it with a terminal or a chat linked WiFi component to recognize commands the user typed. Description. Barotrauma submarine editor tutorial. Connect the output from the Reactor to 1 Junction Box only. If reactor is badly damaged wear a diving suit (PUCS grants high resistance) and stack with a hazmat suit and iodide potassium before proceeding as usual to prevent getting instantly fully irradiated/contaminated. All Discussions. e. 1 Submarine Power Statistics 6 Related Talents 7. . This is a comprehensive guide to creating a two component reactor controller in both submarine editor and active games. #3. technologies to collect and exchange data between the Controller and central data servers and applications. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. . That's insane. 11) This guide first explains some advanced features of the Barotrauma reactor system and then combines a PD controller with some reverse engineering of Barotrauma's source code to build a working fission controller. You can alter the expression of the REGEX component [1-x] to be as high as 9. The fission rate controls how the fuel rods are reacting, making the reactor hotter or colder as needed. If basic automation is not enough for you - your team is doing something wrong, or the boat is not improved. To overvolt or undervolt, simply multiply the load by the desired voltage before sending it into the circuit. Banäne Nov 20, 2021 @ 5:01am. 1. Once that gets above a certain threshold, alarms start to go off, as well as the RCS Fault alarm. Kastrull: 10000. >Uncontrolled mining AI immediately removes suit in high pressure area. 3 Fuel 2. it is not practical though. wiring up a reactor controller and automatic lighting in the. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. Rewiring Components to Reactor. I've added a section with answers for your other questions. This makes it great to control your reactor from overheating! The Manual Control! Don’t be scared of the manual control. To be honest, with those Uber powerful reactor control circuits, the only reason to BE an engineer was for the tree. But, when that pump drops below 25%, the coolant slows and stops flowing. All Discussions. Putting in 4 fuel rods and manually controlling the reactor's fission/cooling rate will make the rods last longer. The battery then powers the junction boxes directly. The battery rarely takes damage because of the logic control, and the junction boxes rarely take damage as well because batteries update their output almost. Automating turbine output control was easy, since it's just a straight percentage of max power out of the reactor. I'm not. The dev team has effectively neutered ALL (AND I MEAN ALL) custom auto reactors down to the shitty vanilla auto reactor. Barotrauma is a survival horror game that will let you control the submarine to explore the deeper and darker regions of oceans in the world. The two-component ARC is not as fuel efficient as the four-component ARC which doesnt even use RegEx. With the removal of the auto reactor systems (of which I liked) I have to ask to those who preferred manual managing of the reactor, why? Why is it more enjoyable to you? I don't understand how sitting handcuffed to the reactor and staring at it for an hour toggling things up or down is fun to do. How to instantly to blow up reactor without melting - barotrauma sabotage / traitor tutorial. What are the advantages: Batteries can compensate Power spikes in both ways. Automatic reactor venting. You can check the reactor durability by either going to the Status Monitor and clicking the Electrical View (green is good, red is bad), or equipping a screwdriver and pressing the Repair button. 01 * Reactor's max output) Fission rate = (Turbine output * 75) / fuel_out The components should be: 1) Memory for "0. Well this is new info to me. Opinions on the numbe. It allows remote control of a submarine's nuclear reactor, except for the movement of fuel rods. In it, some experienced engineer did lengthy explanation abt his research on the scheme. if u truly want a carefree reactor with overvoltage protection, u would also need a battery buffer. Automated meltdown free reactor control, if you want (and can), you should improve it!Good luck out there! About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright. In Barotrauma terms--on an in-game reactor, SET_FISSIONRATE and SET_TURBINEOUT are both parameters that can be. Which would be a linear decrease in fuel consumption, however this isn't the case x is a function of y and when we increase the number of rods we. Barotrauma Workshop. 0000001 seconds. Assuming you're talking about builder. The end result takes 7 components to build, can handle any number of fuel rods safely, can never overheat, and is up to 87. 875. There are also fun things to do, like converting airlocks into secondary ballast tanks, or building motion sensors into the turrets that blast anything that comes close. They are the target of Salvage Missions. It acts as the submarine's main power source for all installations. A submarine file containing pre-wired assemblies for new-style Magic Reactor Controllers for your learning pleasure. The 3-component controller, for example, was not strictly speaking the best, but the one you could have on the boat very quickly. Each suit is lovingly crafted with both personality and function, helping to distinguish job roles and reinforcing the job performance of. First, good component based reactor controllers are still much better then built-in one. Although I suppose as long as you aren't the one doing the. Things covered:0:00 Overview0:39 Buttons, switches, levers. if you wanted, you could create different regexes for different reactor outputs. I'm wondering if anyone has fully upgraded the orca 2 and if it can get to the point where reactor output can meet the load with uraniumExample: reactor has 2000 max output, submarine somehow reaches 4000 load, which causes the controller to calculate turbine value of 200 and set the fission rate based on that 200, but since the turbine can't be set higher than 100 now the fission rate is 2x higher than it should be which can result in a reactor meltdown. Optional: Disconnect terminal. Reply. R-29: 5200. A reactor is useless with broken junction boxes. The nuclear reactor is the source of almost all the power on board the submarine. In-depth Reactor Guide and Fission Controller (last updated for 0. 875 is then inserted into SET_FISSIONRATE, thus making the reactor operate at 46-47% fission rate, depending on the rounding. Repair reactor. This builds off of work done by ignis with the classic 5 component reactor controller, with @WorkingJoe and @Ecchi'ki Senpai pitching in. Info Tab. Cynunnos 8 days ago. 3: Barsuk. u can only use the five component one. Made clown and husk events and missions more common. Typhon 2: 5000. Wire door to set off C4 or IC4 on a delay fuse. The 3-component controller, for example, was not strictly speaking the best, but the one you could have on the boat very quickly. Herja by far, Typhon is currently THE most buggy and outdated ship in the whole vanilla roster. it uses an PI controller to manage the reactor load. Open the console. Only issue I have is that you need to turn off and on the reactor when switching fuel rods, otherwise it risks overheating and catching on fireI like the winterhalter more. In the reactor. LtDWolf • 1 yr. Subscribe to downloadAntoneeees Auto reactor room. If max is 5000, record 50 in the mem comp. Turn off reactor and wait until its lights are out => reduce repair failure to 0%. by PhineasJNX. Members Online. 25. Its only taken me an hour to master this. Aim Assist determines how close the cursor has to be to an item in a Submarine for it to be selected. This outputs -100 to 100 (adjusted by the neutral ballast value). Over-volting does seem to be not as damaging now, which is great. The dev team has effectively neutered ALL (AND I MEAN ALL) custom auto reactors down to the shitty vanilla auto reactor. 11) This guide first explains some advanced features of the Barotrauma reactor system and then combines a PD controller with some reverse engineering of Barotrauma's source code to build a working fission controller. You connect smoke detector output to a relay with 'signal 1' and 'set state' meaning if detector sends 0 (meaning no smoke) it shuts down whole relay and any signal is blocked until detector sends a 1. They are faster, will get more power from one rod and keep temperature to required minimum. This workshop page was mainly created to serve as a user manual for this controller, since i use it on a lot of my submarines. #3. When the components are correctly configured the sliders will bounce between 0 and 100. There is one minor disadvantage: when you're running on a single uranium rod and your load is above 80% of your reactor's output it will under-fission itself and cause undervoltage. Even an external controller will not stop the reactor from catching fire unless you do it like this. 800 sec Dimensions: 498x278 Created: 2/28/2023, 11:32:03 AMThis eventually means that you'll run into ALL of these issues in every single round. 2*. There is nothing we can do. A new automatic reactor controller (ARC) designed specifically for the Hoist the Sails that can be built during a campaign and does not require the sub editor. Description.